Gas Chromatography and Mass spectrometry combines two powerful techniques to provide the identification of compounds with low detection limits and the potential for quantitative analysis
Liquid, gaseous and solid samples work well with GC-MS analysis. However, analyzed compounds are typically volatile and semi-volatile
In Gas Chromatography (GC), a sample is volatilized and carried by an inert gas through a coated glass capillary column. The “stationary phase” is bonded to the interior of the column. Retention time is how long that a compound takes a pass through the column to the detector. Finally, the sample is identified by comparing the sample with a reference
In the usual Mass spectrometry step of GC-MS, compounds leaving the GC column are fragmented by electron impact. The charged fragments are detected and the subsequent spectrum obtained can be used to identify the molecule Fragmentation patterns are reproducible and can be used to produce quantitative measurements.
GC-MS analysis of liquids, gases and solids
Gas Chromatography Mass Spectrometry analyses are performed on liquids, gases or solids. For liquids and gases, the sample is commonly directly injected the GC. For solids, the analysis is carried out by solvent extraction, outgassing(desorption) or pyrolysis
High performance-to-price ratio, low maintenance, long term stable industry or lab use
Small, light and easy to carry
Electronic pressure/flow control system (EPC) on GC-MS improves baseline stability and sensitivity
The newly designed ion optics system optimizes ion yields and transmission characteristics, effectively improving the sensitivity and resolution, while reducing neutral particle noise
EI filaments provide high efficiency of electron emission pre-quad removes un desirable contamination before the main analytical quadrupole and decreases cleaning frequency
New chemical Ionization (CI) source expands range of applications
Sample Introduction system: New industrial design is simple and elegant, with a distinctive, user-friendly GC control panel, Interface was designed with protection from user error in mind
Simple and practical direct liquid and solid inlet probe option allows fast structural analysis of unknown compounds, providing a powerful tool for chemical synthesis applications
Unique removable probe heater is easy to replace in case of damage or contamination. The maximum temperature is 6500C
Compatible with standard conventional GC columns<
Optional auto sampler: Innovative liquid autosampler can rotate 3600C on the horizontal plane. The autosampler can be easily removed from the mount to simplify the GC maintenance
Powerful Software System
Users can easily reference all relevant information during the analysis
Instrument status parameters are displayed in real-time. Alarms are shown in noticeable colors. The automated low vacuum protection function protects fragile parts such as the filament, detector etc.
Modes: Scan, Selected Ion-Monitoring (SIM)
All analysis parameters can be controlled through software, including carrier gas flow, pressure, column oven temperature, inlet temperature etc
High level safety precautions- Auto power shut off
Analyzed methods can be easily exported and imported
The excellent performance of the GC-MS makes it suitable for applications in various fields;
Food Safety and Fragrance
Environmental Safety
Beverages & Liquors
Agriculture and Pesticides
Research & Development labs
Pharmaceuticals
Biological
Geochemical Research
Forensic Applications
Features:
High performance-to-price ratio, low maintenance, long term stable industry or lab use
Small, light and easy to carry
Electronic pressure/flow control system (EPC) on GC-MS improves baseline stability and sensitivity
The newly designed ion optics system optimizes ion yields and transmission characteristics, effectively improving the sensitivity and resolution, while reducing neutral particle noise
EI filaments provide high efficiency of electron emission pre-quad removes un desirable contamination before the main analytical quadrupole and decreases cleaning frequency
New chemical Ionization (CI) source expands range of applications
Sample Introduction system: New industrial design is simple and elegant, with a distinctive, user-friendly GC control panel, Interface was designed with protection from user error in mind
Simple and practical direct liquid and solid inlet probe option allows fast structural analysis of unknown compounds, providing a powerful tool for chemical synthesis applications
Unique removable probe heater is easy to replace in case of damage or contamination. The maximum temperature is 6500C
Compatible with standard conventional GC columns<
Optional auto sampler: Innovative liquid autosampler can rotate 3600C on the horizontal plane. The autosampler can be easily removed from the mount to simplify the GC maintenance
Powerful Software System
Users can easily reference all relevant information during the analysis
Instrument status parameters are displayed in real-time. Alarms are shown in noticeable colors. The automated low vacuum protection function protects fragile parts such as the filament, detector etc.
Modes: Scan, Selected Ion-Monitoring (SIM)
All analysis parameters can be controlled through software, including carrier gas flow, pressure, column oven temperature, inlet temperature etc
High level safety precautions- Auto power shut off
Analyzed methods can be easily exported and imported
The excellent performance of the GC-MS makes it suitable for applications in various fields;
Food Safety and Fragrance
Environmental Safety
Beverages & Liquors
Agriculture and Pesticides
Research & Development labs
Pharmaceuticals
Biological
Geochemical Research
Forensic Applications
All Products
- Auto sampler
- DIP 100 liquid/solid direct injection probe assembly
- Thermal desorption device
- Dynamic headspace sampler
- Purge-and-trap sample concentrator
- Optional: Laser Printer