+447979485982

Molecular Spectrophotometer

Fluorescence Spectrophotometer Double Beam UV Visible Spectrophotometers With GLP/GMP/21 CFR Part 11 Double Beam UV-Visible Spectrophotometers Single Beam UV-Visible Spectrophotometers Colorimeters

Colorimeter FC-1

Wavelength Range 420nm - 660nm
Filters 405nm,492nm,546nm,578nm,600nm(Glass Filters) Or 420,470, 530,620,660nm (Glass filters)
Wavelength Stability Highly reproducible
Repeatability 5nm

Fluorescence Spectroscopy Fluoro-830T

Wavelength Range(Ex.&Em.) : 300nm - 700nm
Accuracy : ± 2nm
Repeatability : ≤ 1nm
Slit (Ex. & Em.) : 12 nm
Standard Excitation wavelength 365 nm
Zero Drift ±0.3%
Peak Intensity Reproducibility ≤ 1.5%

Fluorescence Spectroscopy Fluoro-840

  • S/N Ratio: ≥150(10 nm slit)
  • Optional: S/N≥20(10nm Slit)
  • Wavelength Scan Speed: Multi-speed Level, Maximum at 48000nm/min,
  • Optional: 60,000 nm/min.
  • Optional: Variable Bandwidth models (2nm、5nm、10nm、20nm)

UV Visible Spectrophotometer UV-110

Wavelength Range : 200 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-110PC

Wavelength Range : 200 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-210

Wavelength Range : 200 nm to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-210PC

Wavelength Range : 200 nm to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-310

Wavelength Range : 190 nm to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-310PC

Wavelength Range : 191 nm to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-410C

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-5100

Wavelength Range : 190nm-1100nm
Accuracy : ± 1.5 nm
Repeatability : ± 1 nm
Setting : Manual Turn Knob (0.5 nm minimum)
Photometric Mode : T, A, C
Accuracy : ±0.5% T
Repeatability : ≤ 0.2% T
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-510CS

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-5200

Wavelength Range : 190nm-1000nm
Accuracy : ± 1 nm
Repeatability : ± 1 nm
Setting : Automatic
Photometric Mode : T, A, C,E
Accuracy : 0.5% T
Repeatability : 0.3 % T
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-5300

Wavelength Range : 190nm-1000nm
Accuracy : ± 0.5 nm
Repeatability : ± 0.2 nm
Scanning Speed : Fast,Medium,Slow
Setting : Automatic
Photometric Mode : T, A, C
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.3%T, ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.15%T, 0.001Abs (0-0.5A),± 0.002Abs (0.5 – 1A)
Spectrum Bandwidth 2 nm

UV Visible Spectrophotometer UV-5400VB

Wavelength Range : 190nm-1000nm
Accuracy : ± 0.1 nm@656.1nm,± 0.3nm@all
Repeatability : ± 0.1 nm
Scanning Speed : Hi,Med,Low (Max.3000nm/min)
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.3%T, ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.3%T, 0.001Abs (0-0.5A), ± 0.002Abs (0.5 – 1A)
Spectrum Bandwidth 0.5/1/2/4/5 nm

UV Visible Spectrophotometer UV-5450VB

Wavelength Range : 190nm-1100nm
Accuracy : ± 0.1 nm@656.1nm,± 0.3nm@all
Repeatability : ± 0.1 nm
Scanning Speed : Hi,Med,Low (Max.3000nm/min)
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.2%T(0-100%T), ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.15%T(0-100%T), ±0.002Abs (0-0.5A), ± 0.004Abs (0.5 – 1A)
Spectrum Bandwidth 0.5/1/2/4/5 nm

UV Visible Spectrophotometer UV-610

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-6100

  • Optical System: Double-Beam
  • High performance fixed 2nm spectral bandwidth
  • Operation Mode: Manual & PC Operation
  • Regulatory Compliance with 21CFR Part 11

UV Visible Spectrophotometer UV-610PC

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm

UV Visible Spectrophotometer UV-6200

  • 10.1-inch color touch screen
  • Optical System: Double-Beam
  • High performance fixed 2nm spectral bandwidth
  • Regulatory Compliance with 21CFR Part 11

UV Visible Spectrophotometer UV-6300

  • 10.1-inch color touch screen
  • Double-Beam Spectrophotometer with Spectral Bandwidth: 1 nm
  • Optional: PC software is 21 CFR Part 11 complaint with password method protection, instrument log book, GLP compliance

UV Visible Spectrophotometer UV-6400VB

  • 8-inch color touch screen
  • Spectrum Bandwidth: 0.5nm, 1nm, 2nm, 4nm, 5nm(variable)
  • Optical System: Double Beam
  • Grating: 1600lines/mm
  • Operation Mode: Manual & PC operation

UV Visible Spectrophotometer UV-6500

  • Optical System : Double Beam
  • Grataing: 1800 lines/mm
  • Spectrum Bandwidth: Continuous Slit 0.1- 5nm with 0.1nm Interval
  • Regulatory Compliance with 21CFR Part 11

UV Visible Spectrophotometer UV-710

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 1.8 nm

UV Visible Spectrophotometer UV-710A

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 1.0 nm

UV Visible Spectrophotometer UV-710S

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 0.5 , 1, 2, 4 nm adjustable

UV Visible Spectrophotometer UV-810

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 1.8 nm

UV Visible Spectrophotometer UV-810A

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 1.0 nm

UV Visible Spectrophotometer UV-810S

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.5 , 1, 2, 4 nm adjustable

UV Visible Spectrophotometer UV-910

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1A)
Repeatability : 0.1% τ(0-100%τ) ±0.001 A(0 to 0.5 A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.1,0.2,0.5 nm,1.0,2.0,4 nm

UV Visible Spectrophotometer UV-910PC

Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1A)
Repeatability : 0.1% τ(0-100%τ) ±0.001 A(0 to 0.5 A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.1,0.2,0.5 nm,1.0,2.0,4 nm

Spectrophotometers are widely used for colorimetric applications in various fields of biochemistry, physics and chemical industries. We carry wide array of products suitable for all the specific needs including clinical, laboratory or research and industrial market.

  • Contact Us
  •  info@spectrophotometers.com

Map

Copyright ©2021 Spectrophotometers.com All Rights Reserved