+44 20 8004 3587

Molecular Spectroscopy

Colorimeters Visible Spectrophotometers Single Beam UV-Visible Spectrophotometers Double Beam UV-Visible Spectrophotometers Double Beam UV Visible Spectrophotometers With GLP/GMP/21 CFR Part 11 UV Visible NIR Spectroscopy Fluorescence Spectroscopy
Colorimeter FC-1
Wavelength Range 420nm - 660nm
Filters 405nm,492nm,546nm,578nm,600nm(Glass Filters) Or 420,470, 530,620,660nm (Glass filters)
Wavelength Stability Highly reproducible
Repeatability 5nm
Fluorescence Spectroscopy Fluoro-830T
Wavelength Range(Ex.&Em.) : 300nm - 700nm
Accuracy : ± 2nm
Repeatability : ≤ 1nm
Slit (Ex. & Em.) : 12 nm
Standard Excitation wavelength 365 nm
Zero Drift ±0.3%
Peak Intensity Reproducibility ≤ 1.5%
Fluorescence Spectroscopy Fluoro-840
  • S/N Ratio: ≥150(10 nm slit)
  • Optional: S/N≥20(10nm Slit)
  • Wavelength Scan Speed: Multi-speed Level, Maximum at 48000nm/min,
  • Optional: 60,000 nm/min.
  • Optional: Variable Bandwidth models (2nm、5nm、10nm、20nm)
UV Visible Spectrophotometer UV-110
Wavelength Range : 200 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-110PC
Wavelength Range : 200 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-210
Wavelength Range : 200 nm to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-210PC
Wavelength Range : 200 nm to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-310
Wavelength Range : 190 nm to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-310PC
Wavelength Range : 191 nm to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-410C
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-5100
Wavelength Range : 190nm-1100nm
Accuracy : ± 1.5 nm
Repeatability : ± 1 nm
Setting : Manual Turn Knob (0.5 nm minimum)
Photometric Mode : T, A, C
Accuracy : ±0.5% T
Repeatability : ≤ 0.2% T
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-510CS
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-5200
Wavelength Range : 190nm-1000nm
Accuracy : ± 1 nm
Repeatability : ± 1 nm
Setting : Automatic
Photometric Mode : T, A, C,E
Accuracy : 0.5% T
Repeatability : 0.3 % T
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-5300
Wavelength Range : 190nm-1000nm
Accuracy : ± 0.5 nm
Repeatability : ± 0.2 nm
Scanning Speed : Fast,Medium,Slow
Setting : Automatic
Photometric Mode : T, A, C
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.3%T, ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.15%T, 0.001Abs (0-0.5A),± 0.002Abs (0.5 – 1A)
Spectrum Bandwidth 2 nm
UV Visible Spectrophotometer UV-5400VB
Wavelength Range : 190nm-1000nm
Accuracy : ± 0.1 nm@656.1nm,± 0.3nm@all
Repeatability : ± 0.1 nm
Scanning Speed : Hi,Med,Low (Max.3000nm/min)
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.3%T, ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.3%T, 0.001Abs (0-0.5A), ± 0.002Abs (0.5 – 1A)
Spectrum Bandwidth 0.5/1/2/4/5 nm
UV Visible Spectrophotometer UV-5450VB
Wavelength Range : 190nm-1100nm
Accuracy : ± 0.1 nm@656.1nm,± 0.3nm@all
Repeatability : ± 0.1 nm
Scanning Speed : Hi,Med,Low (Max.3000nm/min)
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : 0-200%T, -0.3~3A,0-9999C
Accuracy : ± 0.2%T(0-100%T), ±0.002Abs(0-0.5A), ±0.004A(0.5A-1A)
Repeatability : ≤ 0.15%T(0-100%T), ±0.002Abs (0-0.5A), ± 0.004Abs (0.5 – 1A)
Spectrum Bandwidth 0.5/1/2/4/5 nm
UV Visible Spectrophotometer UV-610
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-6100
  • Optical System: Double-Beam
  • High performance fixed 2nm spectral bandwidth
  • Operation Mode: Manual & PC Operation
  • Regulatory Compliance with 21CFR Part 11
UV Visible Spectrophotometer UV-610PC
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Spectrum Bandwidth 4 nm
UV Visible Spectrophotometer UV-6200
  • 10.1-inch color touch screen
  • Optical System: Double-Beam
  • High performance fixed 2nm spectral bandwidth
  • Regulatory Compliance with 21CFR Part 11
UV Visible Spectrophotometer UV-6300
  • 10.1-inch color touch screen
  • Double-Beam Spectrophotometer with Spectral Bandwidth: 1 nm
  • Optional: PC software is 21 CFR Part 11 complaint with password method protection, instrument log book, GLP compliance
UV Visible Spectrophotometer UV-6400VB
  • 8-inch color touch screen
  • Spectrum Bandwidth: 0.5nm, 1nm, 2nm, 4nm, 5nm(variable)
  • Optical System: Double Beam
  • Grating: 1600lines/mm
  • Operation Mode: Manual & PC operation
UV Visible Spectrophotometer UV-6500
  • Optical System : Double Beam
  • Grataing: 1800 lines/mm
  • Spectrum Bandwidth: Continuous Slit 0.1- 5nm with 0.1nm Interval
  • Regulatory Compliance with 21CFR Part 11
UV Visible Spectrophotometer UV-710
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 1.8 nm
UV Visible Spectrophotometer UV-710A
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 1.0 nm
UV Visible Spectrophotometer UV-710S
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ(0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015A(0.5A to 1 A)
Spectrum Bandwidth 0.5 , 1, 2, 4 nm adjustable
UV Visible Spectrophotometer UV-810
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 1.8 nm
UV Visible Spectrophotometer UV-810A
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 1.0 nm
UV Visible Spectrophotometer UV-810S
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : - 4 to 4 A
Accuracy : ±0.3% τ (0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1 A)
Repeatability : 0.15% τ (0-100%τ) ±0.001 A(0 to 0.5A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.5 , 1, 2, 4 nm adjustable
UV Visible Spectrophotometer UV-910
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1A)
Repeatability : 0.1% τ(0-100%τ) ±0.001 A(0 to 0.5 A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.1,0.2,0.5 nm,1.0,2.0,4 nm
UV Visible Spectrophotometer UV-910PC
Wavelength Range : 190 to 1100 nm
Accuracy : ±0.3 nm
Repeatability : ≤0.1 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Display Range : -4 to 4 A
Accuracy : ±0.3% τ(0-100%τ) ±0.002 A(0 to 0.5 A) ±0.003 A(0.5 A to 1A)
Repeatability : 0.1% τ(0-100%τ) ±0.001 A(0 to 0.5 A) ±0.0015 A(0.5 A to 1 A)
Spectrum Bandwidth 0.1,0.2,0.5 nm,1.0,2.0,4 nm
Visible Spectrophotometer VS-110
Wavelength Range : 320 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 4 nm
Visible Spectrophotometer VS-110PC
Wavelength Range : 320 to 1100 nm
Accuracy : ±0.5 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 4 nm
Visible Spectrophotometer VS-210
Wavelength Range : 325 to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 1 nm
Setting : Manual
Photometric Mode : T,A,C,E
Range : -0.3 to 3A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual
Spectrum Bandwidth 4 nm
Visible Spectrophotometer VS-210PC
Wavelength Range : 325 to 1000 nm
Accuracy : ±2.0 nm
Repeatability : 1 nm
Setting : Manual
Photometric Mode : T,A,C,E
Range : -0.3 to 3A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual
Spectrum Bandwidth 4 nm
Visible Spectrophotometer VS-310
Wavelength Range : 325 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm
Visible Spectrophotometer VS-310PC
Wavelength Range : 325 to 1000 nm
Accuracy : ±1.0 nm
Repeatability : 0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.5% τ
Repeatability : 0.2% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm
Visible Spectrophotometer VS-410
Wavelength Range : 320 to 1000 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual
Spectrum Bandwidth 2 nm
Visible Spectrophotometer VS-410PC
Wavelength Range : 320 to 1000 nm
Accuracy : ±0.5 nm
Repeatability : ≤0.2 nm
Setting : Automatic
Photometric Mode : T,A,C,E
Range : -0.3 to 3 A
Accuracy : ±0.3% τ
Repeatability : 0.15% τ
Operation Mode Manual & PC Operation
Spectrum Bandwidth 2 nm

Spectrophotometers are widely used for colorimetric applications in various fields of biochemistry, physics and chemical industries. We carry wide array of products suitable for all the specific needs including clinical, laboratory or research and industrial market.

  • Contact Us
  •  82A James Carter Road, Mildenhall Industrial Estate, Suffolk IP28 7DE, United Kingdom
  • +44 20 8004 3587
  •  info@spectrophotometers.com

Map

Copyright ©2021 Spectrophotometers.com All Rights Reserved