Optical System– Double Beam
Wavelength Range– 190 ~1100 nm
Spectral Bandwidth– 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector– Silicon photo diode
Photometric Accuracy– ±0.3%T (0~100%T); ±0.002A (0~1A)
more..
|
|
 |
Optical System– Double Beam
Wavelength Range– 190~900nm
Spectral Bandwidth– 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
Detector– Photomultiplier
Photometric Accuracy– ± 0.3%T (0~100%T), ± 0.002A (0~0.5A), ± 0.004A (0.5A~1A)
more..
|
|
 |
Optical System– Single Beam
Wavelength Range– 190 - 1100nm
Spectral Bandwidth– 2nm (5nm, 4nm, 1nm, 0.5nm optional)
Detector– Silicon photodiode
Photometric Accuracy– 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
more..
|
|
 |
Optical System– Single Beam
Wavelength Range– 190 - 1100nm
Spectral Bandwidth– 2nm (5nm, 1nm optional)
Detector– Silicon photo-diode
Photometric Accuracy– 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)
more..
|
|
 |
Wavelength Range– 190 - 1100 nm
Spectral Bandwidth– 5nm (1, 2, 4nm optional)
Detector– Silicon Photodiode
Photometric Accuracy– 0.5% T
more..
|
|
| Visible Spectrophotometer L-VIS–400 |
|
 |
Optical System– Single Beam
Wavelength Range– 320 - 1100nm
Spectral Bandwidth– 2.0nm (5nm, 1nm optional)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)
more..
|
|
| UV-VIS Split Beam Spectrophotometers - LUV 1000 Series |
|
 |
Optical System– Split Beam
Wavelength Range– 190–1100nm
Spectral Bandwidth– 2nm fixed slit
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
more..
|
|
 |
Optical System– Split Beam
Wavelength Range– 190–1100nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)
more..
|
|
| UV- VIS Double Beam Spectrophotometers- LUV 1000 Series |
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 1100nm
Spectral Bandwidth– 2nm (fixed slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 1100nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
|
| UV- VIS Double Beam Spectrophotometer- LUV 1000E |
|
 |
Optical System– Double Beam
Wavelength Range– 190 – 900nm
Spectral Bandwidth– 0.5, 1, 2, 5nm (Variable slit)
Detector– Silicon photodiode
Photometric Accuracy– ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)
more..
|
| |
|
| Optional Accessories for UV-VIS Spectrophotometers 1000 Series |
| • |
Specular reflection unit |
| • |
Automatic 8-cell holder |
| • |
Changeable Angles Solid Samples Cell Holder |
| • |
Solid sample cell holder |
| • |
Dual-Channels sipper pump |
| • |
Constant-temperature cell holder |
| • |
50mm Long-pathlength cell holder |
| • |
Short-pathlength cell holder |
| • |
Peltier thermoelectric cell holder |
| • |
Test Tube Holder |
| • |
Micro-cell holder |
| |