Atomic Absorption Spectrophotometers– LAAS Series

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret– 6

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret–6

  • more..

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–4

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The  S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame; 5cm single slot all titanium burner for oxygen rich flame.

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • more..

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The     S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–4.
  • Lamp Current Adjustment–Automatic adjustment and display.Wide pulse current: 0~25mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • more..

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)

  • more..

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The   S-H background correction capability at 1.8A is better than 30 times.
  • Lamp Number– 2 lamps (one preheating).
  • Burner– 10cm single slot all titanium burner.

  • more..

  • Wavelength Range– 190-900nm
  • Background Correction– Deuterium lamp 1.0 Abs
  • Burner– Titanium alloy burner

  • more....