Atomic Absorption Spectrophotometer Model AAS-004 offers baseline stability of ≤0.005A/30min and spectral bandwidth of 0.1nm, 0.2nm, 0.4nm, 1.2nm with automatic change over. The unsurpassed basic performance of the Atomic Absorption Spectrophotometer Model AAS-004 along with the built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument satisfies the wide-ranging analytical needs of demanding customers.

Features:

  • High cost-effctive flame AAS
  • Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users
  • Reliable integration of main unit with microprocessor
  • Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument
  • Simple and easy operation
  • Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis

Specifications:

Function Expansion:
Hydride vapor generator can be connected for hydride analysis ≤1%
Dimension:
1020 (L) × 492 (W) × 540 (H)mm
Weight:
80kg , Unpacked

Main Specification:

Wavelength Range:
190nm
900nm
Wavelength Accuracy:
±0.5nm
Resolution:
Two spectral lines of Mn at 279.5nm and 279.8nm can be energy separated with the spectral bandwidth of 0.2nm and valley- peak ratio less than 30%
Baseline stability:
≤0.005A/30min
D2 Lamp Background Correction:
1A better than 30 times

Optical System:

Monochromator:
Single beam, Czerny turner design grating monochromator
Grating:
1800 l/mm
Focal length:
277mm
Blazed Wavelength:
250nm
Spectral Bandwidth:
0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change

Flame Atomizer:

Burner:
10cm single slot all-titanium burner
Spray chamber:
Corrosion resistant all-plastic spray chamber
Nebulizer:
High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Position adjustment:
Manual adjusting mechanism for verical, horizontal positions and the roatation angle of the burner/min.
Gas line protection:
Fuel Gas leakage Alarm/min

Detection and Data Processing System:

Detector:
R928 Photomultiplier with high sensitivity and wide spectral range
Electronic and micro-computer system:
Automatic adjustment of light source power. Light energy and negative high-voltage auto-balance
Display mode:
LEC display of energy and measurement values, concentration direct reading.
Read mode:
Transient, time average, peak height, peak area, integral time is selectable in the range of 0.1~19.
Scale expansion:
0.1~99
Data processing mode:
Automatic calculation of mean, standard deviation and relative standard deviation. Reporting number is in the range of 1~99
Measurement mode:
Automatic cureve fitting with 3~7 standards; Sensitivity auto-correction

Characteristics Concentration and Detection Limit:

Air Acetylene:
Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L

Light Source System:

Lamp turret:
2 lamps are powerd simultaneously (one preheated).
Lamp current adjustment:
0~20mA
Lamp power supply mode:
400Hz square wave pulse.

Product Details:

Add to Cart
Product Name:
Atomic Absorption
Model:
Atomic Absorption Spectrophotometer AAS-004
Unit Price:
Send request for Price: info@SpectroPhotoMeters.com
Quantity:
 
Add to Cart


Other Models:

   Atomic Absorption Spectrophotometer AAS-001

   Atomic Absorption Spectrophotometer AAS-003

   Atomic Absorption Spectrophotometer AAS-007

   Atomic Absorption Spectrophotometer AAS-008

   Atomic Absorption Spectrophotometer AAS-009

   Atomic Absorption Spectrophotometer AAS-010

Atomic Absorption Spectrophotometer Model AAS-004   
Atomic Absorption   
Spectrophotometer   
Atomic Absorption Spectroscopy   
Flame Atomic Absorption Spectrophotometer   
Graphite furnace spectrophotometer   
atomic absorption analysis   
   

Atomic absorption spectroscopy (AAS) determines the presence of metals in liquid samples. Metals include Fe, Cu, Al, Pb, Ca, Zn, Cd and many more.Typical concentrations range in the low mg/L range.Atomic Absorption Spectrophotometer features high-sensitivity analysis, flexible system configuration, and a compact footprint for user-friendly operation

Sign up for Product Updates

 
Send a Request
Name:
Mail ID:
Subject:
Comments: